Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 35 of 256 
15.07.2002 
 
2.27  ATS10  Set disconnect delay after indicating the absence of data carrier 
Read command 
ATS10? 
Response 
<n> OK 
 
Write command 
ATS10=<n> 
This parameter setting determines the amount of time, that the TA remains con-
nected in absence of a data carrier. If the data carrier is detected before discon-
nect, the TA remains connected. 
Response 
OK 
 
 
Parameter 
<n> 001-002-254 
number of tenths of seconds of delay 
Reference 
V.25ter 
Note 
 
 
2.28  ATS18  Extended error report 
Test command 
ATS18? 
Response 
<n> OK  
 
Execute command 
ATS18=<n> 
TA returns an extended report of the reason for the last call release and location. 
 
<n>  
0 – 255, odd numbers set extended error report and even 
numbers disable this feature. 
 
Response 
+Cause: <location ID>: <reason > OK 
 
Parameter 
<location ID> 
Location ID as number code (see subclause 9.1.6. 
<reason> 
 
Reason for last call release as number code (see subclause 
9.1.6)
 
Reference 
Siemens 
Note 
This command works for data calls only. For voice calls please use AT+CEER. 
 
 
2.29  ATT  Select tone dialling 
Execute command 
ATT 
Response 
OK 
 
Reference 
V.25ter 
Note
  
No effect for GSM