AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 34 of 256 
15.07.2002 
 
2.24  ATS6  Set pause before blind dialling 
Read command 
ATS6? 
Response 
<n> OK 
 
Write command 
ATS6=<n> 
No effect for GSM 
Response 
OK 
 
Parameter 
<n> 000-255  number of seconds to wait before blind dialling. 
Reference 
V.25ter 
Note 
 
 
2.25  ATS7  Set number of seconds to wait for connection completion 
Read command 
ATS7? 
Response 
<n> OK 
 
Write command 
ATS7=<n> 
Specifies the number of seconds the TA will wait for the completion of the call 
setup when answering or originating a data call. Also referred to as "no answer 
timeout". To put it plainly, this is the time to wait for the carrier signal. If no carrier 
signal is received within the specified time, the TA hangs up.  
 
Response 
OK 
 
 
Parameter 
<n>
0 <n>
 
000 – 060  no. of seconds to wait for connection completion. 
Reference 
V.25ter 
Note 
·  Values greater than 60 cause no error, but <n> will be restored to the maxi-
mum value of 60. 
·  If called party has specified a high value for ATS0=<n>, call setup may fail. 
·  The correlation between ATS7 and ATS0 is important.  
Example: Call setup may fail if ATS7=30 and ATS0=20. 
·  ATS7 is only applicable to data calls. 
 
 
2.26  ATS8  Set number of seconds to wait for comma dial modifier 
Read command 
ATS8? 
Response 
<n> OK 
 
Write command 
ATS8=<n> 
No effect for GSM 
Response 
OK 
 
Reference 
V.25ter 
 