Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 54 of 256 
15.07.2002 
 
3.9  AT+FDFFC  Data Compression Format Conversion 
Test command 
AT+FDFFC=? 
This parameter determines the ME response to a mismatch between the data 
format negotiated for the facsimile session, reported by the +FDCS:DF sub-
parameter, and the Phase C data desired by the controlling application, indi-
cated by the optional +FDT:DF subparameter, or the +FDIS=DF subparameter 
for the +FDR operation. 
Response 
(list of supported
  <df>s) OK 
Parameter 
See write command 
 
Read command 
AT+FDFFC? 
Response 
<df> OK 
Parameter 
See write command 
 
Write command 
AT+FDFFC =<df> 
Response 
OK 
Parameter 
<df
Mismatch checking is always disabled. The controlling ap-
plication has to check the +FDCS: DF subparameter and 
transfer matching data. 
 
Reference 
EIA PN-2388 
Note 