Siemens MC35 User Manual
AT Command Set
MC35_ATC_01_V05.00
Page 55 of 256
15.07.2002
3.10 AT+FDIS Query or set session parameters
Test command
AT+FDIS =?
This command allows the controlling application to sense and constrain the
capabilities used for the current session. It uses +FDIS to generate DIS or
DTC messages directly, and uses +FDIS and received DIS messages to gen-
erate DCS messages.
capabilities used for the current session. It uses +FDIS to generate DIS or
DTC messages directly, and uses +FDIS and received DIS messages to gen-
erate DCS messages.
Response
(list of <VR>s), (list of <BR>s), (list of <WD>s), (list of <LN>s), (list of <DF>s),
(list of <EC>s), (list of <BF>s), (list of <ST>s)
Parameter
See write command
Read command
AT+FDIS?
Response
<cdec> OK
Parameter
See write command
Write command
AT+FDIS =
<VR>,<BR>,<WD>,
<LN>,<DF>,<EC>,
<BF>,<ST>
<VR>,<BR>,<WD>,
<LN>,<DF>,<EC>,
<BF>,<ST>
Response
OK
Parameter
Vertical Resolution
VR
0
normal, 98 lpi
1
fine, 196 lpi
Bit Rate
BR
0
2400 bit/s, V.27ter
1
4800 bit/s, V.27ter
2
7200 bit/s, V.29
3
9600 bit/s, V.29
Page Width
WD 0 *)
1728 pixels in 215mm
1
2048 pixels in 255 mm
2
2432 pixels in 303 mm
3
1216 pixels in 151 mm
4
864 pixels in 107 mm
Page Length
LN
0
A4, 297mm
1
B4,
364mm
2 unlimited
length
Data Compression Format DF
0 *)
1-D modified Huffman
1
2-D modified read
2
2-D uncompressed mode
Error correction
EC
0 *)
disable ECM
(Annex A/T.30)
1
enable ECM, 64 bytes/frame
2
enable ECM, 256 bytes/frame
Binary File mode
BF
0 *)
disable BFT
Transfer Mode
1
enable BFT
Scan Time/Line
ST
0 *)
0 ms (at VR= normal)
1
5
ms
2
10
ms
3
10
ms
4
20
ms
5
20
ms
6
40
ms
7
40
ms
*) Note: Only the default value needs to be implemented. Use test command
to check which parameter values are really possible!
to check which parameter values are really possible!
Reference
EIA PN-2388
Note
Used for Faxclass 2 only