3.22  AT+FRM  Receive Data 
Test command 
AT+FRM=? 
Response 
(List of supported modulation modes <mod>s)
 OK 
Parameter 
See write command 
Write command 
AT+FRM=<mod
This command causes the TA to enter the receiver-mode using the modulation 
defined below. An ERROR response code results if this command is issued while 
the modem is on-hook. 
 
Response 
CONNECT 
If error is related to ME functionality: 
ERROR 
 
Parameter 
<mod>
 
96 V.29 
9600 
bps 
 72 
V.29 
7200 
bps 
 48 
V.27ter 
4800 
bps 
 24 
V.27ter 
2400 
bps 
Reference 
TIA/EIA-578 
Note 
Used for Faxclass 1 only 
 
3.23  AT+FRS  Receive Silence 
Write command 
AT+FRS=<time> 
+FRS=n causes the TA to report an OK result code to the TE after <time> 10 mil-
lisecond intervals of silence have been detected on the line. This command is 
aborted if any character is received by the DTE. The modem discards the abort-
ing character and issues an OK result code. An ERROR response code results if 
this command is issued while the mode is on-hook. 
Response 
OK 
If error is related to ME functionality: 
ERROR 
Parameter 
<time>
  0 – 255  no. of 10 millisecond intervals 
 
Reference 
TIA/EIA-578 
Note 
Used for Faxclass 1 only 
 
3.24  AT+FTH  Transmit Data Using HDLC Framing 
Write command 
AT+FTH=<mod> 
This command causes the TA to transmit data using HDLC protocol and the 
modulation mode defined below. An ERROR response code results if this com-
mand is issued while the modem is on-hook. 
Response 
CONNECT 
Parameter 
<mod>  3 V.21 Ch2 
300 bps 
Reference 
TIA/EIA-578 
Note 