Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 61 of 256 
15.07.2002 
 
3.25  AT+FTM  Transmit Data 
Test command 
AT+FTM=? 
Response 
(List of supported modulation modes)
 OK 
Parameter 
See write command 
 
Write command 
AT+FTM=<mod> 
This command causes the TA to transmit data using the modulation mode de-
fined below. An ERROR response code results if this command is issued while 
the modem is on-hook. 
Response 
CONNECT 
If error is related to ME functionality: 
ERROR 
 
Parameter 
<mod>
  modulation mode 
 96 
V.29 
9600 
bps 
 72 
V.29 
7200 
bps 
 48 
V.27ter 
4800 
bps 
 24 
V.27ter 
2400 
bps 
 
Reference 
TIA/EIA-578 
Note 
Used for Fax class 1 only 
 
 
3.26  AT+FTS  Stop Transmission and Wait 
Write command 
AT+FTS=<time> 
This command causes the TA to terminate a transmission and wait for <time> 10 
millisecond intervals before responding with the OK result code to the DTE. 
Response
 
An ERROR response code results if this command is issued while the modem is 
on-hook. 
 
Parameter 
<time>  0 – 85  no. of 10 millisecond intervals 
 
Reference 
TIA/EIA-578 
Note 
Used for Fax class 1 only