4.24  AT+CLVL  Loudspeaker volume level 
Test command 
AT+CLVL=? 
Response 
+CLVL: (list of supported <level>s)OK 
 
Read command 
AT+CLVL? 
Response 
+CLVL: <level> 
OK/ERROR/+CME ERROR 
 
Write command 
AT+CLVL=<level> 
Response 
OK/ERROR/+CME ERROR 
Parameter 
<level>  Loudspeaker Volume Level (0-4) 
 
 
Reference 
GSM 07.07 
Note 
·  The write command can only be used in audio mode 2 – 6. 
·  The values of the volume steps are specified with the parameters 
<outCalibrate[0]>,...<outCalibrate[4]> of the AT^SNFO command (see 
Chapter 8.24).  
·  As an alternative to AT+CLVL, you can use AT^SNFO and AT^SNFV 
(Chapter 8.27). The parameter <level>  is identical with <outStep> 
used by both commands.  
·  Any change to <level> (or <outStep>) takes effect in audio modes 2 to 
6. That is, when you change <level> (or <outStep>) and then select 
another mode with AT^SNFS, the same step will be applied.  
The only exception is audio mode 1 which is fixed to <level>=4 (or ac-
cordingly <outStep>=4). 
·  <level> (or <outStep> is stored non-volatile when the ME is powered 
down with AT^SMSO or reset with AT+CFUN=1,1.