ACS hdg User Manual

Page of 37
 
Chapter 3: Installation 
15 of 37 
 
When the customer is providing either the motor or the starter, the machine must be wired in 
accordance with the basic electrical diagram and the starter manufacturer’s instructions.  
Use the following procedure to complete the electrical connections:  
1.  Check to be certain that the starter heater elements correspond with the motor 
requirements. If controls are not supplied, the limit switches supplied on the machine 
must be wired into the circuit at the common terminal box.  
2.  Check that the limit switches are closed.  
3.  Turn switch ON at main power supply. 
4.  Jog motor by pressing the START and then the OFF button. This starts and stops the 
motor.  
5.  With the electrical power ON, check that the motor rotates in a clockwise direction at 
the viewing port in the belt guard. If motor rotation is correct, continue to the next 
step. If rotation is incorrect, complete the following procedure: 
a.  Shut power OFF and disconnect incoming power supply.  
b.  Reverse any two of the three power line connections to the machine.  
c.  Re-connect the incoming power supply line and turn ON the main power 
switch to recheck motor drive rotation.  
6.  If Airveying system (optional) is fitted, press the Airveyor START button and check 
the blower motor rotation. The blower motor should rotate in a counter clockwise 
direction. If blower motor rotation is correct, continue to step 7. If blower motor 
rotation is incorrect, complete the following procedure:  
a.  Shut power OFF and disconnect incoming power supply line.  
b.  Reverse any two of the three power connections to the blower motor.  
c.  Re-connect the incoming power supply line and recheck the blower motor 
rotation.  
7.  Allow all motors to run up to speed for at least 30 seconds.  
   
 
3-4  Accessing the Cutting Chamber 
You will need to access the cutting chamber before initial startup and for various 
maintenance procedures. Use the following procedure to access the cutting chamber:  
1.  Turn main power off, remove the line fuses and tag the machine as out of service. 
2.  Remove the hex head bolts on the outside corners of the cutting chamber covers.  
This will disengage the safety switches. 
3.  Remove the center plate connecting the two doors and then remove the remaining 
bolts around the doors to free them from the cutting chamber. 
4.  The doors are attached to support arms that swing the covers outward and away from 
the chamber using the handles that are provided on each cover.  
5.  Back out the bolt wedges (5 per side on 72B) holding the screen cradle in place. 
6.  Once the cradle is free and the base is clear of any obstructions the pneumatic 
cylinders can be activated to lower the cradle.