ACS hdg User Manual

Page of 37
 
Chapter 3: Installation 
16 of 37 
 
 
 
 
 
 
 
 
 
 
 
 
 
3-5  Closing the Cutting Chamber 
After completing any maintenance or adjustments inside the cutting chamber, use the 
following procedures to close the cutting chamber and resume use of the granulator:  
1.  Replace the screen and activate the pneumatics to raise the screen cradle 
2.  Reinsert the bolt wedges to lock in the screen cradle. (5 on 72B per side) 
3.  Swing the cutting chamber doors back into their closed position and replace bolts.  
4.  Replace bolts activating the safety switches to signal the doors are closed and tight. 
5.  Rotate the rotor by hand from outside the machine to check that no tools, gauges, or 
loose parts have been left on or in the machine.  
6.  Replace line fuses, turn power on, and remove the “Out of Service” tag from the 
machine.