example, when connections are initiated by a controlling 
system such as the Bosch Video Client or the Bosch Video 
Management System. The camera connects to all remote 
stations protected by the same general password. To define a 
general password:
1.
Select 10 in the Number of destination IP address list 
box.
2.
Enter 0.0.0.0 in the Destination IP address field.
3.
Enter the password in the Destination password field.
4.
Set the user password of all the remote stations to be 
accessed using this password.
Setting destination 10 to the IP-address 0.0.0.0 overrides its 
function as the tenth address to try.
12.1.5
Video transmission
If the device is operated behind a firewall, select TCP (HTTP 
port) as the transfer protocol. For use in a local network, select 
UDP.
To enable multicast operation, select the UDP option for the 
Video transmission parameter here and on the Network page.
Note:
In the event of an alarm, a larger network bandwidth is 
sometimes required for additional video streams (if multicast 
operation is not possible). 
12.1.6
Remote port
Select an appropriate browser port depending on the network 
configuration. The ports for HTTPS connections are only 
available if the On option in SSL encryption is selected.
12.1.7
Video output
If a decoder device is used, select the analog video output to 
which the signal should be switched. If the destination device is 
unknown, select the First available option. This places the 
image on the first video output with no signal. 
The connected monitor only displays images when an alarm is 
triggered.