Deflector Remote 
1. Remove e-ring and flat washer from stud 
on discharge chute.
2. Route deflector remote cable between the 
chute and the chute pedestal.
3. Slide cable end through hole on bracket on 
left side of chute (Figure 7).
4. Attach cable eye to stud on deflector. Hold 
in place with flat washer and e-ring.
5. Check deflector travel. Adjust nut on cable 
end under handlebar to obtain full travel. 
(See Deflector Remote in Service and 
Adjustments
.)
Check Function of Dual Handle 
Interlock
Without the engine running, press down 
(engage) both clutch levers. Release 
attachment clutch lever. Attachment clutch 
should remain engaged until traction clutch 
lever is released, then both clutches must 
disengage. If they do not, contact your dealer 
for repairs.
Check Tire Pressure
Check tire pressure and adjust to the pressure 
listed on tire sidewall.
Check Auger Gearcase Oil
Check oil level in auger gearcase (see Service 
and Adjustments
).
Check Engine Crankcase Oil
IMPORTANT: The engine is shipped with 
5W-30 oil in crankcase. Refer to Engine 
Manual for detailed instructions.
Fill Engine Fuel Tank
Refer to Engine Manual for proper fuel type 
and tank capacity.
Check Function of all Controls
Ensure unit runs and performs properly. Refer 
to Operation.
Figure 6
1. Spring Clip
2. Chute Crank Rod
3. Universal Joint
OS6640
Figure 7
1. Cable Eye
2. Flat Washer and E-Ring
3. Deflector Cable