SMSC EVB-EMC2101 User Manual

Page of 12
EVB-EMC2101 User Manual
 SMSC EMC2101
Revision 1.5 (12-13-06)
9
3.8
  LED Indicators
LEDs indicate the status of the following signals (
).
3.9
  Jumper Settings
This EVB has many jumper configurations to evaluate all of the features of the EMC2101. 
3.9.1
Device Power 
To enable one of the 2 devices on the EVB, use jumpers J2 and J3. When a device is selected, the
appropriate LED will light as shown in 
 below summarizes the options. Note: only
one device may be active at a time as both devices have the same SMBus address.
3.9.2
Fan Control
To adjust the fan control circuit one 3-way jumper is used. The two settings are DAC mode and PWM
mode. The default setting is PWM which requires the fan to be connected to FAN CONN. 1 and the
JP8 shorted from pin 1-2. 
If the linear DAC mode is desired, several things need configured. First, JP8 must be shorted from pin
2-3 and the fan must be connected to FAN CONN. 2. Then, the device must be configured for linear
operation via the ChipMan software. Consult the datasheet for these settings.
Table 3.1  LED Status Indicators
LED
SIGNAL
OFF
GREEN
RED
LED1
ALERT
+3.3V power OFF
No ALERT
ALERT
LED2
+3.3V
+3.3V power OFF
+3.3V power ON
NA
LED3
Bridge Activity
NO Activity on 
USB/SMBus Bridge
Activity on 
USB/SMBus Bridge
NA
LED4
USB Activity
NO Activity on USB port
Activity on USB port
NA
LED5
EMC2101 
Power
U10 power OFF
U10 power ON
NA
LED6
EMC2101-R
Power
U11 power OFF
U11 power ON
NA
Table 3.2  Device Power
JUMPER
NAME
 POSITION 1-2
POSITION 2-3
J2
EMC2101 POWER
U10 power ON
U10 power OFF
J3
EMC2101-R POWER
U11 power ON
U11 power OFF
Table 3.3  Fan Driver Configuration
FAN DRIVER 
CONFIGURATION
JP8
FAN CONNECTOR
PWM
 Position 1-2
P9
DAC
Position 2-3
P5