2.2  POWER SUPPLY 
 
  Power  can  be  supplied  using  an  internal  re-chargeable 
battery  provided  within  the  indicator  case,  or  from  mains 
power. 
 
 
If the battery is low on charge the symbol on the LCD will 
show just one bar  
 meaning the battery needs to be re-
charged immediately. While the battery is being re-charged, 
this symbol will show four bars.
 
 
  With the internal re-chargeable acid battery, the battery life is 
approximately 60 hours. The battery life will vary depending 
on the use of the backlight 
2.3  LOAD CELLS 
 
  To  connect  the  AE  301  indicator  to  a  new  base  it  is 
necessary  to  connect  the  load  cells  properly.  Then  set  the 
parameters for the weighing system.  
 
  User should ensure the load cells are correct for the purpose 
and the signal from the load cell is correct. 
 
  Note  that  it  may  not  be  possible  to  measure  the  voltage 
signal  from  the  load  cell  with  all  DVM.    Some  DVM  will 
measure  the  Excitation  and  signal  voltage  while  others  will 
not.  Try measuring the excitation voltage to determine if your 
voltmeter will work. 
  
 
CONNECTING TO LOAD CELLS 
 
The AE 301 is supplied with a connector to connect an external 
load cell.    
 
The  load  cell  can  be  connected  in  either  a  4  or  6-wired 
configuration. The standard connection is 4 wired.   
 
Pin 1   
Excitation + 
Pin 2   
Excitation – 
Pin 3   
Signal + 
Pin 4   
Signal –