TRIGger:SEQuence3:SOURce
TRIGger:ACQuire:SOURce
TRIGger:ACQuire:SOURce
These commands select the trigger source for a triggered measurement sequence as follows:
BUS
GPIB device, *TRG, or <GET> (Group Execute Trigger)
EXTernal
ac source’s backplane Trigger In BNC
TTLTrg
the signal driving the Trigger Out BNC
Command Syntax
TRIGger:SEQuence3:SOURce <CRD>
TRIGger:ACQuire:SOURce <CRD>
TRIGger:ACQuire:SOURce <CRD>
Parameters
BUS | EXTernal | TTLTrg
*RST Value
BUS
Examples
TRIG:ACQ:SOUR BUS TRIG:SEQ3:SOUR EXT
Query Syntax
TRIGger:SEQuence3:SOURce?
TRIGger:ACQuire:SOURce?
TRIGger:ACQuire:SOURce?
Returned Parameters
<CRD>
Related Commands
ABOR TRIG TRIG:DEL TRIG:SYNC
TRIG:SYNC:PHAS INIT INIT:CONT *TRG WAI
TRIG:SYNC:PHAS INIT INIT:CONT *TRG WAI
TRIGger:SEQuence1:DEFine
TRIGger:SEQuence2:DEFine
TRIGger:SEQuence3:DEFine
TRIGger:SEQuence2:DEFine
TRIGger:SEQuence3:DEFine
These commands define the names that are aliased to trigger sequences 1, 2 and 3. The command
accepts only TRANsient for sequence 1, SYNChronous for sequence 2, and ACQuire for sequence 3 as
predefined names. The query allows the user to query the instrument names aliased to sequences 1, 2,
and 3.
accepts only TRANsient for sequence 1, SYNChronous for sequence 2, and ACQuire for sequence 3 as
predefined names. The query allows the user to query the instrument names aliased to sequences 1, 2,
and 3.
Command Syntax
TRIGger:SEQuence1:DEFine TRANsient
TRIGger:SEQuence2:DEFine SYNChronous
TRIGger:SEQuence3:DEFine ACQuire
TRIGger:SEQuence2:DEFine SYNChronous
TRIGger:SEQuence3:DEFine ACQuire
Parameters
TRANsient, SYNChronous, ACQuire
*RST Value
BUS
Examples
TRIG:SEQ1:DEF TRAN TRIG:SEQ3:DEF ACQ
Query Syntax
TRIGger:SEQuence1:DEFine?
TRIGger:SEQuence2:DEFine?
TRIGger:SEQuence3:DEFine?
TRIGger:SEQuence2:DEFine?
TRIGger:SEQuence3:DEFine?
Returned Parameters
<CRD>