*CLS
This command clears the following registers (see Chapter 4 under “Programming the Status Registers” for
descriptions of all registers):
u
Standard Event Status
u
Operation Status Event
u
Questionable Status Event
u
Status Byte
u
Error Queue
Command Syntax
*CLS
Parameters
None
*ESE
This command programs the Standard Event Status Enable register bits. The programming determines
which events of the Standard Event Status Event register (see *ESR?) are allowed to set the ESB (Event
Summary Bit) of the Status Byte register.  A "1" in the bit position enables the corresponding event. All of
the enabled events of the Standard Event Status Event Register are logically ORed to cause the Event
Summary Bit (ESB) of the Status Byte Register to be set. See Chapter 4 under “Programming the Status
Registers” for descriptions of the Standard Event Status registers.
The query reads the Standard Event Status Enable register.
Bit Configuration of Standard Event Status Enable Register
Bit
Position
7
6
5
4
3
2
1
0
Bit Name
PON
not
used
CME
EXE
DDE
QYE
not
used
OPC
Bit Weight
128
32
16
8
4
1
PON  Power-on
DDE
Device-dependent 
error
CME
Command error
QYE
Query error
EXE
Execution error
OPC
Operation complete
Command Syntax
*ESE <NRf>
Parameters
0 to 255
Power-On Value
see *PSC
Examples
*ESE 129
Query Syntax
*ESE?
Returned Parameters
<NR1>
Related Commands
*ESR?     *PSC     *STB?