Adtran MX2800 M13 User Manual

Page of 200
MX2800 M13 Multiplexer User Manual
Configuration, Section 3
61200290L1-1G
    3-37
Equipment Codes
The Equipment Code
 
supports 10 alpha-numeric characters and provides user-configurable text strings to 
identify the MX2800 over the network.
Syslog Setup
These selections include Transmission, Host IP Address, Severity Level, and Host Facility. 
Transmission
This option enables or disables the transmission of log events to the external Syslog server. The host IP 
address must be defined first.
Host IP Address
This option specifies the IP address of the external server that is running the Syslog host daemon.
Severity Level
This option specifies the lowest level of severity that causes messages to be logged to the Syslog server. 
The levels are listed in 
 in order of decreasing severity. Any message at or above a selected sever-
ity level will be logged if a transmission is enabled.
Host Facility
This option specifies the facility destination of log events. Facilities are located on the host and are 
managed by the Syslog host daemon running on either a UNIX machine or a PC. Options include 
Local 0-
7
.
Table 3-6.  Syslog Severity Levels
Level
Description
Emergency 
The system is unusable.
Alert 
An action must be taken immediately.
Critical Shows 
critical 
conditions.
Error Shows 
error 
conditions.
Warning Shows 
warning 
conditions.
Notice 
Shows normal but significant conditions.
Info
Shows informational messages.
Debug 
Shows a debug-level message.