Polycom 7000 User Manual

Page of 323
NetEngine IAD User Guide
WAN Configuration
81
Configuring
 
ATM PVCs
You may configure up to 8 ATM PVCs on the IAD. To configure create and 
manage PVCs, type 
3
 on the WAN configuration menu. The IAD displays 
the ATM PVC Configuration menu:
Figure 4–36.  ATM PVC Configuration Menu 
Type the option to perform a task. Proceed to the corresponding section.
u
Adding a New PVC (page
)
u
Modifying an Existing PVC (page
u
Deleting an existing PVC (page
u
Displaying the Current PVCs (page
Adding a PVC
To add a PVC, follow these steps:
1. On the ATM PVC Configuration menu, type 
1
 to select Add New PVC.
2. The IAD displays a prompt for the VPI:
Enter Virtual Port Identifier (VPI):
Type a VPI value between 0 and 255 (default 0) and press Enter.
3. The IAD displays a prompt for the VCI:
Enter Virtual Circuit Identifier (VPI):
Type a VCI value between 32 and 65535 (default is 38 for data, 39 for 
voice) and press Enter.
*****************************************
ATM PVC Config Menu
*****************************************
1. Add New PVC
2. Modify Existing PVC
3. Delete PVC
4. Show Current PVCs
 
NOTE
Before you configure PVCs, you must first set the datalink 
protocol to ATM. If option 3 on the WAN Configuration menu 
displays Configure DLCIs instead of Configure PVCs, it is 
because your datalink protocol is set to Frame Relay instead 
of ATM.