Maytag electric dyer User Manual

Page of 72
4
 INSTALLATION INSTRUCTIONS 
TOOLS AND PARTS
Gather the required tools and parts before starting installation. Read and follow the 
instructions provided with any tools listed here. 
Parts supplied
Remove parts packages from dryer drum. Check that all parts are included.
4 Leveling legs
Parts needed
Check local codes. Check existing electrical supply and venting. See “Electrical 
Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from 
the dealer from whom you purchased your dryer. For further information, please refer to the 
“Assistance or Service” section of this manual.
LOCATION REQUIREMENTS 
You will need
A location that allows for proper exhaust installation. See “Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical outlet located within 2 ft 
(61 cm) of either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The 
combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater 
than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not 
tumble properly and models with automatic sensor cycles may not operate correctly if 
dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer 
might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or 
weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in 
garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that 
opens to 1" (2.54 cm) or 
hex-head socket wrench 
(for adjusting dryer feet)
Wire stripper (for U.S. 
only, direct wire 
installations)
Tin snips (new vent 
installations)
Level
Vent clamps
Caulking gun and 
compound (for installing 
new exhaust vent)
Tape measure
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as 
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor 
for a garage installation.