ELECTRICAL CONNECTION - U.S.A. ONLY
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
 
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 
³⁄₄" (1.9 cm) UL listed strain relief (UL marking on strain 
relief). Put the tabs of the two clamp sections into the hole below the terminal block 
opening so that one tab is pointing up and the other is pointing down, and hold in 
place. Tighten strain relief screws just enough to hold the two clamp sections together. 
Power Supply Cord
Direct Wire
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord. 
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
A. Terminal block cover
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Hold-down screw location
E. Neutral ground wire
F. Hole below terminal block opening
A
B
C
D
E
F
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
A
B
C
D