Runco plasmawall xp-50dhd, xp-50dhdxa, xp-65dhd, xp-65dhdxa, xp-103dhd User Manual

Page of 80
PlasmaWall XP Series Owner’s Operating Manual
41 
PRE
L
IMINAR
Y
Color Saturation: On your external test pattern source, select a color bar pattern like the 
one shown in Figure 4-4. 
Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint
Select Color and press ENTER. While looking at the color bar pattern through a blue filter, 
adjust the color saturation level until the outermost (gray and blue) color bars appear to be 
a single shade of blue: 
Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. 
When tint is decreased, the image appears redder; when it is increased the image 
appears greener. To set the tint, select Tint and press ENTER. While looking at the color 
bar pattern through a blue filter, adjust the tint level until the cyan and magenta color bars 
(on either side of the green bar) appear to be a single shade of blue. 
Like the brightness and contrast controls, the color and tint controls 
are interactive. A change to one may require a subtle change to the 
other in order to achieve the optimum setting. 
gray
yellow
cyan
gr
een
magenta
re
d
blue
gray
yellow
cyan
gr
een
magenta
re
d
blue
Note