Chamberlain Swing GATE User Manual

Page of 54
28 of 53 
Doc 6001242 (01-20273) 
Rev C 
2.  BI-PARTING LATCH GATE DETAILS 
The Bi-Parting Latch Gate is typically used in low traffic residential sites due to its ease of use and 
added security of magnetic locking.  The Bi-Parting Latch configuration can consist of any combination 
of models SL 1000-B1 (slide gate), SW 2000-B1 (swing gate) and BG 3000-B1 (barrier gate). 
STREET
COMPLEX
Gate
Operator
Master
Gate
Operator
Slave
Exit Loop
Inside Interrupt
 Loop
Shadow Loop
Outside Interrupt
 Loop
Fence
Fence
INPUTS:
Radio
Cycle
Interrupt Bar
Fire
MagLock
Manual
   Inputs
SWITCH S1
SETTINGS:
Slide: Unit
Option
Timer: Sys.
Option
Retry: Sys.
 Option
ATG: Sys.
Option
Master: ON
Trap: OFF
SWITCH S1
SETTINGS:
Slide: Unit
      Option
Timer: OFF
Retry: OFF
ATG: OFF
Master: OFF
Trap: OFF
1204F21
Master/Slave Cable
Connect MagLock to one unit only.
For safety, setting MUST
be the same for both units.
 
Figure 17.  Typical Bi-Parting Latch Gate Installation 
HOW IT WORKS:  
•  The Master moves first during opening and Slave first during closing, with a 2 second delay 
between them to prevent gate intercollision and to ensure proper latching.  When the gates are fully 
closed, the outer edge of the Master gate rests on the outer edge of the Slave. 
•  A fault in one unit affects both units (see Troubleshooting/Maintenance for Fault List). 
•  A continuous FIRE input in either gate opens the gates and holds them open. 
There are 3 different ways to close the gates (entering or exiting): 
1.  Reclose Timer: When the Reclose Timer expires, gates close automatically. 
2.  ATG and Interrupt Loop: With ATG ON, clearing the Inside Interrupt Loop closes the gates. 
3.  Alternate Action:  
With ATG and TIMER OFF, RADIO or CYCLE commands close fully open gates.
 
WARNING:  The Power Fail Operation Option can be used ONLY on the Master Unit.  To maintain all 
gate functions during power outages, use a full UPS (Uninterruptable Power Supply) on each unit. 
INPUT CONNECTIONS:  (for more details, refer to paragraph L, Connecting Input Wiring) 
•  Inputs can be connected to either gate.  For enhanced safety, the Interrupt Bar, Interrupt Loop, and 
Shadow Loop inputs may be connected to both gates. 
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS 
Gate 
Type 
SLIDE 
ACTION 
(Reclose) 
TIMER 
RETRY 
ATG 
MASTER 
TRAP 
Operator 
Inputs 
Bi-Parting 
Latch 
Unit 
Optiono 
System 
Optionn 
System 
Optionn 
System 
Optionn 
ON OFF 
Systemp 
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS 
Bi-Parting 
Latch 
Unit 
Optiono 
System 
Optionn 
System 
Optionn 
System 
Optionn 
OFF OFF 
Systemp 
n
Select ATG, Timer and/or Retry from the Master unit and set Slave ATG, Timer and Retry to OFF.  Otherwise, the 
ATG ON/shorter Reclose Timer/Retry ON in either unit supersedes the other. 
o
:
  For safe and reliable operation, this setting MUST be the same for both units (see Appendix A). 
p
Inputs to one unit affect both gate operators, so you can connect inputs to either unit.