There are 2 different ways to close the gate (entering or exiting): 
1.  Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave). 
2.  Interrupt Loop; clearing the Inside Interrupt Loops cause the gates to close (Master or Slave). 
NOTE:  To ensure gate closure, set Reclose Timer =ON in both Master and Slave 
INPUT CONNECTIONS:  (for more details, refer to Part 2, Paragraph L, Connecting Input Wiring) 
•  Master and Slave units require their own separate inputs. 
•  If Radio inputs are used in both units, each requires its own transmitter and entry code. 
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS 
Gate 
Type 
SLIDE 
ACTION 
(Reclose) 
TIMER 
RETRY 
ATG 
MASTER 
TRAP 
Operator 
Inputs 
Trap 
Unit 
Optionn 
Unit 
Optionn 
Unit 
Optionn 
ON ON ON 
Unito 
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS 
Trap 
Unit 
Optionn 
Unit 
Optionn 
Unit 
Optionn 
No Effect 
OFF 
OFF 
Unito 
n
:
  Master and Slave units can have different Reclose Timer settings. 
o
Inputs affect one gate operator only, so connect inputs separately to each gate operator.