CLRCO2075 — Clear Ice Maker/Refrigerator
3. Carefully bend the water supply line into position and 
connect the line to the solenoid valve (see Figure 39). 
Avoid kinking the water supply line.
IMPORTANT
Normal operation creates some vibration. A water supply 
line contacting cabinet wall may cause excessive noise 
during operation or damage to the line.
4. For recessed installations, allow extra water supply line 
length to provide slack for easy removal from the 
recessed area (see Figure 39). This will also safeguard 
against kinking the line. 
5. Go on to 7 Prepare Power Supply.
Electrical Specifications
CAUTION
Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A power supply (normal household current). 
An individual, properly grounded branch circuit or circuit 
breaker is recommended. GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be 
sure to consult your local codes.
See Figure 40 for recommended receptacle location. 
Plugging the unit into a receptacle located behind an 
adjacent cabinet will allow the CLRCO2075 to be more 
easily serviced with self-diagnostics without disturbing 
your installation.
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.
• Never use an extension cord to connect power to 
the unit.
Go on to 8 Level the Unit.
Power
Cord
Water Line
Figure 39
7 Prepare Power Supply
Acceptable
Location
Preferred
Location
for CLRCO2075
Receptacle
1-1/2"
7"
24"
Figure 40