DO  NOT  CONNECT  TO  AC  DISTRIBUTION  WIRING:  the  inverter  is  engineered  to  be  
connected directly to standard electrical and electronic equipment in the manner described above. 
Do not direct wire the power inverter to household or RV AC distribution wiring. Do not connect 
the power inverter to any AC load circuit in which the neutral conductor is connected to ground 
(earth) or to the negative of the DC (battery) source.
CAUTION: RECHARGEABLE APPLIANCES
Certain rechargeable devices are recharged by plugging them directly into an AC receptacle. 
when first using a rechargeable device, monitor its temperature for the initial ten minutes of use 
to determine whether it becomes warmer than usual. If excessive heat is generated, it is a good 
indication that the device should not be used with this inverter. This problem does not occur with 
the majority of battery-operated equipment. Most of these devices use a separate charger or 
transformer that is plugged into an AC receptacle. This inverter is easily capable of powering 
most chargers and transformers.
4.5   PLACEMENT OF THE POWER INVERTER
For best operating results when used away from the main unit, the inverter should be placed on a 
flat surface, such as a vehicle seat or floor. Keep in mind that the inverter will generate heat – the 
larger the AC load the more heat generated. Position the Inverter so that a casual brush against 
a hot inverter surface will not distract a driver. 
WARNING: Inverters generate heat while operating. Power inverters should only be used in  
    locations that meet the following criteria:
DRY –  Do not allow water or other liquids to come into contact with the inverter.
COOL  –  Ambient  air  temperature  should  be  between  30  degrees  F  (-1  degree  C)  
non-condensing, and 105 degrees F (40 degrees C). do not place the inverter on or near a  
heating vent or any piece of equipment that is generating heat above room temperature. Keep 
the inverter away that from direct sunlight, if at all possible.
VENTILATED  – Keep the area surrounding the inverter clear to ensure free air circulation around 
the unit. Do not place items on or over the inverter during operation. The unit will shut down if 
the internal temperature gets too hot. Restart the unit after it cools.
SAFE  –  Do  not  use  the  inverter  near  flammable  materials  or  in  any  locations  that  may  
accumulate flammable fumes or gases.
4.6   OPERATING TIPS
Rated  versus  actual  current  draw  of  most  equipment–electrical  tools,  appliances  and  
audio/video equipment have labels that indicate the power consumption in amps or watts. Be 
sure that the power consumption of the item you wish to operate is rated at 200 watts or less.  
(If  the  power  consumption  is  rated  in  amps  AC,  simply  multiply  by  the  AC  volts  (120)  to  
determine the wattage). The inverter has overload protection, so it is safe to try to operate equip-
ment rated at 200 watts or less. The inverter will shut down if it is overloaded and will restart 
once the overload is removed.
Resistive loads are the easiest for the inverter to run; however, larger resistive loads, such as electric 
stoves or heaters, require more wattage than the inverter can deliver. Inductive loads, such as TV’s 
and stereos, require more start-up current to operate than do resistive loads of the same wattage 
rating. Induction motors, as well as some televisions, may require 2 to 6 times their wattage rating 
to start up. The most demanding in this category are those that start under load, such as compres-
sors and pumps. Testing is the only definitive way to determine whether a specific load can be 
started and how long it can run. The unit will simply shut down if it is overloaded. To restart the 
unit after a shutdown due to overloading, momentarily turn off the power to the unit.
THE  INVERTER  WILL  NOT  OPERATE  HIGH  WATTAGE  APPLIANCES  OR  EQUIPMENT  THAT   
PRODUCE HEAT, SUCH AS HAIR DRYERS, MICROWAVE OVENS AND TOASTERS.