Vector power city dk080706 User Manual

Page of 20
8
4.2   PRINCIPLES OF OPERATION
The  power  inverter  converts  power  in  two  stages.  The  first  stage  is  a  DC-to-DC  conversion 
process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage 
is the actual inverter stage that converts the high voltage DC into 120 volts, 60 Hz AC, Modi-
fied Sine Wave (MSW). MSW is a waveform that has characteristics similar to the sine wave 
shape of utility power. This type of waveform is suitable for most AC loads, including linear and 
switching power supplies used in electronic equipment, transformers, and motors. The modified 
sine wave produced by the power inverter has an RMS (root mean square)  voltage of 120 
volts, which is the same as standard household power. Most AC voltmeters (both digital and 
analog) are calibrated for RMS voltage under the assumption that the waveform measured will 
be a pure sine wave. These meters will NOT READ the RMS voltage of a modified sine wave  
correctly. They will read about 20 to 30 volts low when measuring the output of the power inverter. 
For accurate measurement of the output voltage of this unit, use a voltmeter marked “TRUE RMS”. 
Figure 5 compares a Modified Sine Wave with a True Sine Wave.
FIGURE 5
The Power Inverter is incorporated into the Power City main unit. It’s DC source is the main unit’s 
12 volt, 19AH battery. Power is provided to the inverter through two flat contacts on the bottom 
of the inverter. The inverter operates on stored energy in the main battery. With a full charge on 
the main battery, the inverter will supply a load of 100 watts for approximately one hour and 5 
minutes. Lower wattage loads will operate longer, higher wattage loads will operate for a shorter 
time using energy from the main battery.
When  the  inverter  is  operated  away  from  the  main  unit,  the  power  source  must  provide  
between 11 and 14.5 volts DC and must be able to supply the necessary current (amps) to operate 
the load. The power source may be a battery or a well-regulated DC power supply. To obtain a 
rough estimate of the current (in amperes) that the power source must deliver, simply divide the 
power consumption of the load (in watts AC) by 10.
Example:  If  a  load  is  rated  at  100  watts  AC,  the  power  source  must  be  able  to  deliver:  
100 / 10 = 10 amperes
CAUTION: The inverter must be connected only to batteries with a nominal output voltage of  
    12 volts. The unit will not operate from a 6 volt battery and will sustain permanent           
    damage if connected to a 24 volt battery.
The inverter may be used whether or not the vehicle’s engine is running. However, the inverter 
may not operate while the engine is starting since the battery voltage can drop substantially  
during engine cranking. The inverter draws less than 0.06 ampere from the battery when it is 
not supplying power to a load.
4.3   CONNECTING INVERTER TO POWER SOURCE AWAY FROM MAIN UNIT
The Inverter can be used away from the main unit by removing it from it’s mounting on the 
main unit and powering it from the Inverter power cable, located in the storage compartment 
in the back of unit.  The power inverter has two flat metal contacts that normally mate with the  
connector on the main unit. These flat contacts are connected to the inverter power cable (black 
and red color) when the inverter is removed from the unit and operated away from the unit. The 
inverter power cable comes equipped with a 12 volt DC plug. The tip of the plug is positive and 
the side contact is negative. Connect the power inverter to the power source by inserting the DC 
plug firmly into the accessory outlet of a vehicle or other DC power source. The connection to 
the accessory outlet can be improved by slightly rotating the plug in the socket. (See Figures 6 
and 7)