C120-E360-06EN
CHAPTER 2  Setup of the RCI for Operation 
2.6
RCI Setup for Replacement of an RCI Base 
Cabinet
2.6.1
RCI setup flow
RCI setup for replacement of an RCI host contains the following steps:
1
2
3
4
5
Note:
Perform this RCI setup work for each RCI host to be replaced.
 
2.6.2
Replacing an RCI host
Remove the T-branch connector together with the RCI cable from the RCI host to be 
replaced, and replace the RCI host with a new one. 
Do not connect the removed T-branch connector to the new RCI host at this time.
2.6.3
Confirming RCI initialization
Before connecting an RCI cable again to a new RCI host, confirm that RCI settings 
have been initialized.
• To confirm RCI initialization:
1
Execute the setrci (8) command to display the RCI status.
Confirm that the "address" value is 000f7fff (initial address value).
If RCI settings have not been initialized, perform the next step.
XSCF> setrci -c stat
HOST
 address 000f7fff
 Inactive
The command completed successfully.