4
123
123
123
123
B
A
Cool down
This function allows to gradually lower the temperature of the wash bath to
prevent creasing of the linen.
During a cool down, the remaining program time on the central display will be
replaced by “cd”.
Power Failure
Should the power fall out during the program, the water will be drained and the
door can be opened after maximum 3 minutes.  When the door remains locked,
and the power comes back up within 24 hours, the program will continue from
there, where it was at the time of the power failure.
If due to breakdown, the door is not unlocked automatically, you have to remove
the service panel (A) below and pull the ring (B), suspended on the left side, while
opening the door.
Important:
Central panel control (Option)
Here payment is done through the central panel and not directly into the
machine.
  As soon as the payment is done, and a machine has been selected
normally, “STA” appears blinking on the left display.  The machine can be
started by pressing the START button or the special START button, which has
been built in on the spot of the coin meter (option).
Before opening the door, check that all the water has been drained from
the tub and that the cylinder has come to a complete stop.
Remark :
This option can only be used, when it has actually been programmed as such
in the programmation.(REMOTE START).
For certain versions, PAY can appear on the left display when this operation
is not active.
Therefore, “Remote PAY” was programmed in the programmation.
Thermo-magnetic motor protection
If the program switches off due to overheating of the motors and the thermo-
magnetic protection
 shuts them down, the left display will alternately show
Mot” and the temperature of the wash bath. This can occur during:
washing
All movement is halted but the water remains in the tub. When the motors switch
back on again, the program will continue to run where it left of.
spinning
All movement is halted and the water is drained. When the motors are switched
on again, the spinning phase will be skipped.
Remark
If the thermo-magnetic motor-protection switches on for the fifth time during
the same program, this program will be immediately terminated.