Defaulting the Printer:  To reset only the communications parameters on 
the printer to the factory defaults (9600 baud, 8 bit word length, no parity, 
1 stop bit, and XON/XOFF), press and hold the PAUSE, FEED, and 
MODE buttons while turning on the printer, then release the buttons when 
the CALIBRATE LED goes out.  All of the LEDs turn on, while the 
DARKEN, POSITION, and CALIBRATE LEDs flash.  Press and hold the 
MODE button until all of the lights go out, then release the MODE button.  
The factory defaults have now been reset.  Next, set the communications 
parameters on your computer to match this.
NOTE:  To save the default settings, press the MODE button four 
times.  Otherwise, the previous settings are restored the next time 
the printer is turned on.
Autobaud:  To automatically detect the communications parameters, press 
and hold the PAUSE, FEED, and MODE buttons while turning on the 
printer, then release the buttons when the CALIBRATE LED goes out.  All 
of the LEDs turn on, while DARKEN, POSITION, and CALIBRATE 
LEDs flash.  Send a label format using the host computer settings.  If the 
printer accepts the host parameters, all of the LEDs turn off (except for the 
POWER LED) and the printer restarts with the host communication 
settings.  If the printer does not accept the host communications 
parameters, the printer does not restart and the LEDs flash on and off.  If 
this should happen, turn the printer off and then on, and try again.
NOTE:  Label formats sent to the printer at this time only help the 
printer determine the host settings.  No label prints until settings are 
recognized.
NOTE:  In order for autobaud to work, your label must start with 
either a 
^XA
 or 
~XA
 ZPL II command.  If all the LEDs are on, send 
another label format.
NOTE:  Save the new communication settings by pressing MODE 
four times.
NOTE:  Autobaud only works for 9600 baud and higher.