Jacuzzi j-300 j-355 User Manual

Page of 64
8
J-300 
3.3 
Important additional Csa safety Instructions (Canada only)
When using this electrical equipment, basic safety precautions should 
always be followed, including the following:
1.
  reaD anD Follow all InsTruCTIons.
2.  A green colored terminal or a terminal marked G, Gr, Ground, 
Grounding or the   symbol* is located inside the supply terminal box 
or compartment. To reduce the risk of electric shock, this terminal 
must be connected to the grounding means provided in the electric 
supply service panel with a continuous copper wire equivalent in size 
to the circuit conductors that supply this equipment (*IEC Publication 
417, Symbol 5019).
3.  At least two lugs marked “Bonding Lugs” are provided on the 
external surface or on the inside of the supply terminal box/
compartment. To reduce the risk of electric shock, connect the local 
common bonding grid in the area of the spa to these terminals with 
an insulated or bare copper conductor not smaller than No. 6 AWG 
(10 mm²).
4.  All field installed metal components such as rails, ladders, drains or 
other similar hardware within 10 feet (3m) of the spa shall be bonded 
to the equipment grounding buss with copper conductors not smaller 
than No. 6 AWG (10 mm
2
).
5.
  save THese InsTruCTIons.
3.4 
General electrical safety Instructions
Your new Jacuzzi spa is equipped with a “state-of-the-art” equipment 
system. It contains the most advanced safety and self-protective 
equipment in the industry. Nonetheless, this spa must be installed 
properly to ensure dependable usage. Please contact your local Jacuzzi 
dealer or local building department should you have any questions 
regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with 
a current collector system. A pressure wire connector is provided on the 
surface of the control box, located outside the equipment door (Figure 
and any ground metal equipment, metal water pipe or conduit within 5 
feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet 
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²) 
solid copper wire. This is a most important safety assurance feature.
Before installing your spa, check with your local building department to 
insure installation conforms to local building codes.