Nortel Networks 5399 User Manual

Page of 126
4-11
Chapter 4
Troubleshooting Procedures
Nortel Networks 5399 Access Switch Hardware Installation Guide
The IP encapsulation type. All systems that have Ethernet
interfaces are IEEE 802.3 compliant, but very few actually
do 802.3 (LLC/SNAP) packet encapsulation. Use the
default, Ethernet, unless you know absolutely that your LAN
does 802.2/802.3 (LLC/SNAP) packet encapsulation.
You can use the defaults for the name of the image file containing the
Remote Access Concentrator’s software and the address of the preferred
load server host. If the value for the image name is incorrect, the Remote
Access Concentrator cannot boot. Correct the name using the image
command. If the address for the preferred load server host is incorrect,
the boot takes longer, since the Remote Access Concentrator has to
broadcast for a host. Correct the load host’s address using the addr
command.
Confirm that the Remote Access Concentrator’s boot parameters are
correct by using the appropriate ROM Monitor commands. Modify any
boot parameters that are incorrect or missing. Boot the Remote Access
Concentrator either by entering the boot command at the service port
terminal, or by resetting the module.
Load Server Host Not Responding
The Remote Access Concentrator can boot from one of the following
hosts acting as a load server host:
A UNIX host on the LAN using BFS via erpcd.
Another Remote Access Concentrator using BFS.
Any host (UNIX or non-UNIX) using tftp.
A Windows NT host using BFS via erpcd.
The following subsections discuss troubleshooting for some of these load
server hosts.