NEC plasmasync 42pd3 User Manual

Page of 70
62
 
 †
P
LASMA
 M
ONITOR
Appendix
47. CONFIG MENU Select
Function
The master monitor selects the CONFIG set-
tings of the slave.
Transmission data
CFH  UA1  UA2  06H  01H  DATA00  CKS
DATA00
Bit0 Bit1 : OSD DISPLAY
0
0
: BASIC
1
0
KEY
0
1
OFF
0
0
disabled
Bit2
0 : OSD MODE BASIC
1 : OSD MODE PRO
Bit3 Bit4 : SYNC CONTROL
0
0
AUTO
1
0
GSYNC
0
1
CSYNC
Bit5
0 : PLE LINK OFF
1 : PLE LINK ON
Bit6,7
0 (fixed)
ACK
6FH  UA1  UA2  06H  01H  DATA00  CKS
48. TIMER PROGRAM Setting
Function
The master sets timer program of the slave.
Transmission data
CFH  UA1  UA2  08H  0CH  DATA00 – DATA11  CKS
DATA00  Program No.
01H – 07H: Nos. 1 – 7
DATA01  Date (Month) Setting
01H – 09H: 1 – 9
10H – 12H: 10 – 12
AAH: When the date (day)  is set to “Every-
day” or “Every Sun. - every Sat.”.
FFH: - (No setting)
DATA02  Date (Day) Setting
00H: Everyday
01H – 09H: 1- 9
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 31H: 30 – 31
40H – 46H: Every Sun. – every Sat.
FFH: - (No setting)
DATA03 ON Time (HOUR)
00H: 00 - 09
10H – 19H: 10 – 19
20H – 23H: 20 – 23
FFH: - (No setting)
DATA04  ON Time (MIN)
00H – 09H: 00- 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
FFH: - (No setting)
DATA05  OFF Time (HOUR)
00H – 09H: 00 - 09
10H – 19H: 10 – 19
20H – 23H: 20 – 23
FFH: - (No setting)
DATA06  OFF Time (MIN)
00H – 09H: 00- 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
FFH: - (No setting)
DATA07  Mode
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
06H:RP
07H:RI
FFH: - (No setting)
DATA08  Repeat Program MODE1
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
FFH: - (No setting)
DATA09  Repeat Program TIME1
00H: 1 min
01H: 2 min
02H: 3 min
03H: 4 min
04H: 5 min
05H: 7 min
06H: 10 min
07H: 15 min
08H: 30 min
DATA10  Repeat Program MODE2
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
FFH: - (No setting)
DATA11  Repeat Program TIME2
00H: 1 min
01H: 2 min
02H: 3 min
03H: 4 min
04H: 5 min
05H: 7 min
06H: 10 min
07H: 15 min
08H: 30 min
ACK
6FH  UA1  UA2  08H  00H  CKS
49. MULTI DISP MODE Select
Function
The master switches DISP MODE of the slave.
Transmission data
CFH  UA1  UA2  07H  02H  DATA00  DATA01  CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.
DATA01 (Spare): DON’T CARE
ACK
6FH  UA1  UA2  07H  02H  DATA00  DATA01 CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.
DATA01 (Spare): DON’T CARE
50. MULTI DISP MODE Request
Function
The master requests the DISP MODE settings
of the slave.
Transmission data
CFH  UA1  UA2  61H  02H  DATA00  DATA01  CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.
DATA01 (Spare): DON’T CARE