NEC plasmasync 42pd3 User Manual

Page of 70
P
LASMA
 M
ONITOR
 
 † 
63
51. PRESENT TIME Setting
Function
The master monitor sets a present time of the
slave monitor.
Transmission data
CFH  UA1  UA2  09H  0AH  DATA00 – DATA09  CKS
DATA00  First two digits of year
19H: indicates 1900s
20H: indicates 2000s
DATA01  Last two digits of year
00H – 09H: 00 – 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
60H – 69H: 60 – 69
70H – 79H: 70 – 79
80H – 80H: 80 – 89
90H – 99H: 90 – 99
DATA02  Month
01H – 09H: 1 – 9
10H – 12H: 10 – 12
DATA03  Day
01H – 09H: 1 – 9
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 30H: 30 – 31
DATA04  Hour
00H – 09H: 00 – 09
10H – 19H: 10 – 19
20H – 23H: 20 – 23
DATA05  Minute
00H – 09H: 00 – 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
ACK
6FH  UA1  UA2  09H  00H  CKS
Appendix