Crestron clti-1mc4 clxi-1mc4 User Manual

Page of 4
 
CLTI- & CLXI-1MC4 
Terminal Block & Module Locations (Single-wide Enclosure) 
Functional Summary 
MODULE
TERMINAL
BLOCK
GROUNDING
TERMINAL
BLOCK
 
The Crestron
 1-Feed, 4-Motor Terminal Block and 
Module (CLTI-1MC4 and CLXI-1MC4, respectively), are 
considered a single entity and must be used together. 
They ship separately to permit termination of the field 
wiring to the CLTI-1MC4 prior to installation of the 
CLXI-1MC4, as described in this guide. They can be 
mounted in any Crestron Automation Enclosure (CAEN-
Series Enclosures). The terminal block is designed to 
terminate the circuit feed (HOT and NEUTRAL) and 
distribute the controlled circuits (LOAD) to the motors. 
The module connects to the terminal block and performs 
control of four bi-directional motors. The maximum load 
is 8 amps (1 HP) for any controlled circuit, limited to 13 
amps total per module. The unit requires 230VAC 50 Hz, 
1 phase input voltage. An oversize heat sink dissipates 
heat efficiently. There are LEDs on the module to indicate 
communication to a Cresnet
 network, input power to the 
module, and output power to the load. 
Installation 
Terminal block and module must be mounted into a 
Crestron Automation Enclosure by a licensed electrician, 
in accordance with all national and local codes.  
Terminal Block & Module Locations (Double-wide Enclosure) 
CAUTION:  This equipment is for indoor use only 
and needs to be air-cooled. Mount in a well-
ventilated area. The ambient temperature must be 
0
°C to 40°C (32°F to 104°F). The relative humidity 
must be 0% to 90% (non-condensing).  
GROUNDING TERMINAL BLOCKS
MODULE
TERMINAL BLOCK
(LEFT)
TERMINAL BLOCK
(RIGHT)
 
Terminal blocks are installed along the left side of single-
wide enclosures and along the outside edges (left and 
right sides) of double-wide enclosures. Modules are 
installed along the right side of single-wide enclosures 
and side-by-side in the center of double-wide enclosures. 
When installing modules and terminal blocks in a double-
wide enclosure, be sure to invert units on the right side so 
that they can be properly wired. Refer to the illustrations 
shown in the next column when considering the location 
of terminal blocks and modules within an enclosure.  
NOTE:  Modules and terminal blocks must be 
installed into the lowest available spaces and 
continue toward the top of the enclosure. 