Crestron cnxrmak User Manual

Page of 4
Rack Mount Kit 
 
Crestron CNXRMAK
 
Installation Instructions 
Component Mounting Locations 
The CNXRMAK can accommodate up to three C2N-HBLOCKs or CNPWS-75s or any combination 
of each. Three sets of mounting holes have been drilled into the mounting plate for each component. 
As shown below, C2N-HBLOCK (s) and/or CNPWS-75(s) are mounted to the holes in the appropriate 
location(s). 
C2N-HBLOCK and CNPWS-75 Mounting Locations 
CNPWS-75
C2N-HBLOCK
CNPWS-75
C2N-HBLOCK
CNPWS-75
C2N-HBLOCK
 
Component Mounting and Rack Installation 
Refer to the procedure below and complete the following steps for proper installation of a  
C2N-HBLOCK (C2N-HBLOCKmounting plate must be removed) or CNPWS-75 onto the 
CNXRMAK and then into a rack.  
1.  Position the CNXRMAK mounting plate so that the rear of the plate faces the rear of the 
component. (The barcode label should be at the bottom of plate, facing the component.)  
2.  As shown in the diagram below, align mounting holes on the plate with threaded holes in 
the rear of the component. Using a #2 Phillips 1/4-inch hex bit and an inch-pound torque 
driver, install four screws (supplied) and tighten to 11-inch pounds (1.24 newton-meters) 
to secure component.  
C2N-HBLOCK Installation   
 
CNPWS-75 Installation 
NOTE:  BARCODE LABEL ON REAR OF PLATE
     
F
E
E
S
U
U
F
S

S
U
F
NOTE: BARCODE LABEL ON REAR OF BRACKET
 
3.  If installing another C2N-HBLOCK or CNPWS-75, repeat this procedure. If not 
installing another component, refer to the diagram on the next page and install the 
CNXRMAK into rack with components facing inward. (Rack mounting hardware is not 
supplied.) 
2  
  Rack Mount Kit: CNXRMAK 
Installation Guide – DOC. 8156A