3.3.3  Tone Open Numbers 
These steps will program the tone open numbers for relays 0, 1 and 2.  You will need to enter a four-
digit number (see chart below) to set the relay functions.  If a function is not desired, enter # in place 
of a number.  For example, if you want the relay to have a momentary activation function only, and 
you want the relay to activate when the number 9 is pressed, enter 9#### in step 4.  Do not duplicate 
tone open numbers, i.e., don’t set relay 0, 1, and 2 tone-open numbers all to 9.  If Tracker expansion 
boards are connected to the system, there is no need to set a momentary open tone open number for 
the tracker control relay(s).  However, you may want to set HOLD and DEACTIVATE tone numbers, 
which will allow management to have a function to automatically unlock all doors/gates controlled by 
a Tracker board (refer to 5.3.1). 
Factory setting is: Relay 0 = ####, Relay 1 = 9876, Relay 2 = 5432
 
1. 
Press *05 and enter the four-digit MASTER CODE _ _ _ _ (beep). 
2. 
Press 0* to set relay 0 or 1* to set relay 1 or 2* to set relay 2 tone numbers. 
3. 
Enter the four-digit tone open number code _ _ _ _ then press * (beep). 
4. 
Repeat steps 2 and 3 to set the other relays tone open numbers. 
5. 
Press 0# TOGETHER to end this programming step (beeeeeep). 
 
DIGIT FUNCTION 
Momentary activation.  Relay will activate for the programmed strike time (3.3.1). 
Relay hold.  Relay will activate and remain activated until commanded to release. 
Relay release.  Deactivates the relay hold command. 
Relay hold 1-hour.  Relay will activate for 1-hour and then will automatically deactivate itself. 
 
 
3.3.4 Postal Switch 
This programming sequence sets that relay(s) will activate when the postal switch input is activated 
on the telephone entry system.  The system can be programmed so that only one relay will activate, 
or any combination of relays will activate.  HINT:  The relay that you designate as the primary relay 
should be programmed to activate from the postal switch input.  To cause a relay to activate, enter a 
1 in it's respective character slot, or enter a zero to not activate the relay.  Any combination of 1's or 
0's is permissible.  For example, entering 010 in step 3 will cause only relay 1 to activate.  Entering 
101 will cause both relay 0 and relay 2 to activate. 
Factory setting = 010
 
1. 
Press *50 and enter the four-digit MASTER CODE _ _ _ _ (beep). 
2. 
Enter the three-digit (1's or 0's only) postal relay code _ _ _ then press * (beep). 
3. 
Press 0# TOGETHER to end this programming step (beeeeeep). 
 
 
35