Washer-Extractors
14
5-08-53
Installation - Model IHF075
Ground
The machine must be placed on a flat, solid surface 
(metal base, concrete or solid ground). It is 
recommended that the machine be anchored on the 
provided places (1) in the base, especially in case of a 
plinth. Refer to Figure 9.
Figure 9 
The machine must be placed entirely level. For easy 
maintenance it is recommended to keep a minimal 
distance of 23.62 in. (600 mm) between the wall and 
the back of the machine.
If several machines are placed next to each other, there 
should be a minimal distance of 1.18 in. (30 mm) 
between each machine.
Electrical Installation Requirements 
- Model IHC075
Table 2 
CHM2180N
1
Mounting Bolt Holes
1
Machine with steam heating or boiler fed 
machines without additional electrical heating
220V 3AC
380V 3AC + N
16 A
16 A
Machine with electrical heating
220V 3AC
380V 3AC + N
18 kW
50 A
32 A
21 kW
N/A
40 A
24 kW
N/A
40 A
30 kW
N/A
50 A