IPSO chm2172n User Manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
14
5-08-53
Installation - Model IHF075
Ground
The machine must be placed on a flat, solid surface
(metal base, concrete or solid ground). It is
recommended that the machine be anchored on the
provided places (1) in the base, especially in case of a
plinth. Refer to Figure 9.
Figure 9
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
Electrical Installation Requirements
- Model IHC075
- Model IHC075
Table 2
CHM2180N
1
Mounting Bolt Holes
1
Machine with steam heating or boiler fed
machines without additional electrical heating
220V 3AC
380V 3AC + N
16 A
16 A
Machine with electrical heating
220V 3AC
380V 3AC + N
18 kW
50 A
32 A
21 kW
N/A
40 A
24 kW
N/A
40 A
30 kW
N/A
50 A