Electrical
Supply Voltage
120V +/- 10%, 60Hz, single phase
Surge Protection
MOV rated for 150V
Power Plug
3-pin grounded
Pass-Through Outlet
Uncontrolled 3-pin (grounded), 120V, 15A
Power Consumption
2.11W
Certification
Safety-tested for use in USA and Canada (ETL #3017581)
Default Application
Maximum Number of Scenes/De-
vices
240
Number of Rooms
15
Scene/Device Commands Sup-
ported
On
Off
Dim
Brighten
Timer Events Supported
1 On and 1 Off timer per day per scene/device
Maximum Number of Timer Events
480 per day (240 On, 240 Off)
Timer Day of the Week Condition
Supported
Browsers Supported
All browsers supported for HTML-only interface;
JavaScript/AJAX enabled browsers for ideal interface use
Linux browsers not currently supported
 Certifications and Warranty
Certification
This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American
ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian
device safety standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up 
inspections to verify continued conformance. 
FCC and Industry Canada Compliance Statement
This device complies with FCC Rules Part 15 and Industry Canada RSS-210 (Rev. 7 or 8). Operation is subject to the following two conditions:
 
(1) This device may not cause harmful interference, and 
 
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorise aux deux 
conditions suivantes: 
 
(1) l’appareil ne doit pas produire de brouillage, et 
 
(2) l’utilisateur de l’appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d’en compromettre le 
                     fonctionnement.
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and televi-
sion reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, 
which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
 
- Re-orient or relocate the receiving antenna of the device experiencing the interference
 
- Increase the distance between this device and the receiver
 
- Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver
- Consult the dealer or an experienced radio/TV technician
WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment. 
ETL/UL Warning (Safety Warning)
CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install this device to control a receptacle, a motor-operated 
appliance, a fluorescent lighting fixture, or a transformer-supplied appliance.
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres
materiels, ne pas installer pour commander une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.