Intel CM8063501287403 User Manual

Page of 232
Intel® Xeon® Processor E5-1600 v2/E5-2600 v2 Product Families
109
Datasheet Volume One of Two
 
Thermal Management Specifications
up to Tcontrol is permitted at all power levels. Compliance to the DTS profile is required 
for any temperatures exceeding Tcontrol.
5.1.5
Thermal Metrology
The minimum and maximum case temperatures (T
CASE
) are measured at the geometric 
top center of the processor integrated heat spreader (IHS). 
 illustrates the 
location where T
CASE
 temperature measurements should be made. For detailed 
guidelines on temperature measurement methodology, refer to the Intel® Xeon® 
Processor E5-1600/2600/4600 v1 and v2 Product Families Thermal / Mechanical Design 
Guide
.
Table 5-4.
Embedded DTS Thermal Specifications
TDP (W)
Model 
Number
Core
Count
T
LA
 (°C)
T
LA-ST
 (°C)
PSI
PA 
(°C/W)
Nominal 
Maximum
T
DTS
 (°C)
Short-Term 
Maximum
T
DTS
 (°C)
LV95W
E5-2658 v2
10
51
66
0.336
82.9
97.9
LV70W
E5-2648L v2
10
49
64
0.489
83.2
98.2
LV70W
E5-2628L v2
8
49
64
0.503
84.2
99.2
LV50W
E5-2618L v2
6
52
67
0.644
84.2
99.2
Figure 5-4. Embedded DTS Thermal Profile