Line 6 AXSys 212 User Manual

Page of 48
Description of Features: Chapter 3
AxSys 212 User Manual
37
Aux Input Reverb
This controls the amount of reverb that is added to the Aux Input signal.
When set to 0, no reverb is added and the Aux Input signal is ÒdryÓ. When
set to 99, the reverb is added at its maximum level and the Aux Input
signal is ÒwetÓ.
Global Controls
The following four controls are found on the far right end of the first top
two Edit Rows. As their name ÒGlobalÓ implies, these four parameters are
set once for all Sounds; i.e. their settings are static and do not change from
one Sound to another.
Parameter
Range
Description
MIDI Channel
01 to 16
Selects the basic MIDI channel.
Transmit Sounds
01A to 32D,
Edit, All
Lets you transmit one or all User Sounds via the
MIDI OUT
 connector.
Gate/Hum Per
Sound
Snd, All
Determines whether the Noise Gate and Hum
Canceller parameters will change when a new Sound
is selected.
Aux Per Sound
Snd, All
Determines whether the Aux Input parameters will
change when a new Sound is selected.
MIDI Channel
The 
MIDI CHANNEL
 parameter determines which of the 16 available MIDI
channels is used to send and receive program changes and controller
messages (controller 7 for Volume, controller 3 for Wah). It can be set
between 
1 and 16.
Transmit Sounds
The 
TRANSMIT SOUNDS
 parameter lets you transmit either a single User
Sound or all User Sounds in memory via the 
MIDI OUT
 connector. This
information can be sent to a MIDI storage device, such as a computer
running a sequencer or editor/librarian software, or to another AxSys 212.
Display
Transmitted via MIDI
01A to 32d
Any single Sound in the User Bank (01-32, A-D)
Edt
The current Sound being edited
ALL
All 128 Sounds in the User Bank
Use the 
TRANSMIT SOUNDS
 parameter to select what you want to transmit.
You can choose any User Sound from 
01A to 32d, or Edt (the current
Sound in the edit buffer) or 
ALL (all Sounds in the User Bank). Once
youÕve made your selection, press the 
STORE
 button to execute the
transmission; the display will temporarily read 
trA.