Hanna Instruments hi 8001 User Manual

Page of 88
50
Y (yes) can be entered next to the selected condition to change the controller
state. Only the Y (yes) key will have effect in activating the appropriate state. This
panel displays and allows the setting of the following parameters:
Stop
Press Y (yes) then ENTER to place the controller in stop state.
Current controller status
Work
Press Y (yes) then ENTER to place the controller in work state.  If there are
certain alarm conditions it is not possible to enter WORK state.
Init
Press Y (yes) then ENTER to place the controller in initialization state.
5.8.4 OUTLET MAN CTRL – S 50
      
Number: 27
     Opened: Y
     Value:  -
OUTLET MAN CTRL S50
In this panel the outlet number is used as the index. See Appendix 2 with outlet
assignment. This panel displays and allows the setting of the following param-
eters:
Number
Panel index.  Outlet number.
Opened
The status of the indexed outlet.
Value
Press Y (yes) or N (no) to open or close the indexed outlet.
5.9 CUSTOMIZED SETTINGS
5.9.1 PH CTRL OPTIONS - S 51
 
 Ctrl in Pre/Post Y
Use acid in pHCtrl Y
pH CTRL OPTIONS  S51
This panel allows selection of pH control options. The control in “pre” and
“post” irrigation states as well as acid/base selection are selectable. This panel
displays and allows the setting of the following parameters: