calorique thermolar tank warming system User Manual

Page of 12
INSULATION
Insulate the tank using the type and thickness insulation indicated
on the System Component List. This insulation factor has been used
to calculate the heating load required by the system: using less insu-
lation may result in contents damage.
O
PERATION
PROGRAMMING
The programmable controller provides four different user-settable
parameters
Maintenance Temperature:
The desired contents temperature.
Differential:
The precision of temperature control.
Over-Limit Temperature:
The highest temperature that the
heating elements, the tank contents or
the tank itself should reach.
Low-Limit Temperature:
The lowest allowable contents
temperature.
OPERA
TION
6
Note
Make sure that the control unit cover is securely in place before insulation is applied to
the tank to ensure that no insulation gets into the control unit itself.
Note
If using blown-on insulation, create a dam around the control unit cover to ensure that
it may be removed to allow for programming and the indicator lights to be seen.
Input Power
Maintenance Sensor
Over Limit Sensor