ge-interlogix simon 3 User Manual
Simon Security System
17
4.
Press Done. The panel announces the set time.
Adding (Learning) Sensors
These instructions describe how to add sensors, touchpads and other system devices
into panel memory. The panel recognizes a sensor when you press a sensor program
button, press and release a tamper switch, press a sensor test button, or put a sensor into
alarm.
into panel memory. The panel recognizes a sensor when you press a sensor program
button, press and release a tamper switch, press a sensor test button, or put a sensor into
alarm.
Note
The hardwire inputs must have sirens or hardwire sensors with 47k Ohm resistors connected
between the DCOUT and HWIN1 or HWIN2 terminals before learning in a sensor. If one of
these connections is not made, the panel will learn in a hardwire zone.
The hardwire inputs must have sirens or hardwire sensors with 47k Ohm resistors connected
between the DCOUT and HWIN1 or HWIN2 terminals before learning in a sensor. If one of
these connections is not made, the panel will learn in a hardwire zone.
Note
If you are installing a sensor on a gun case, jewelry box, or similar usage, and the sensor is
active in level one, you must sub-disarm to avoid putting the panel into alarm when the sensor
and the magnet are separated.
If you are installing a sensor on a gun case, jewelry box, or similar usage, and the sensor is
active in level one, you must sub-disarm to avoid putting the panel into alarm when the sensor
and the magnet are separated.
The following table, “Device Programming,” describes the programming button loca-
tion for each device.
tion for each device.
When adding (learning) sensors, the panel uses an ascending numbering sequence start-
ing with 1. You can override this by entering the desired sensor number using the num-
bered keys.
ing with 1. You can override this by entering the desired sensor number using the num-
bered keys.
Device Programming
Device
To Program
Door/Window Sensor
Press button on top of sensor (cover removed)
or trip tamper
Motion Sensor
Press button on back of sensor (mounting plate
removed) or trip tamper
Smoke Sensor
Trip tamper, press test button, remove from
base or put sensor in alarm
Keychain Touchpad
Press and hold Lock & Unlock buttons together
ELM Keychain Touchpad
Remote Handheld Touchpad
Press the EMERGENCY buttons
2-Way RF Touchpad
Press Lights Off button 6 times
Hardwire Sensors
Separate sensor from magnet
CO Alarm
Plug in the module wait 5-7 seconds press and
hold the test button for 9 beeps
Freeze & Water
Trip tamper or press and hold button on top of
the sensor (cover removed) until control panel
confirms programming. If button is not held
down long enough, SYSTEM STATUS reports
sensor as open.
Dialog RF Electronic Thermostat
Panel automatically recognizes thermostat dur-
ing thermostat power-up.
Press
Hold
Hold
Flash Flash
Flash
Hold until LED is done flashing.
Press
Press
Hold
Flash
Flash Flash