ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
17
4.
Press Done. The panel announces the set time.
Adding (Learning) Sensors
These instructions describe how to add sensors, touchpads and other system devices 
into panel memory. The panel recognizes a sensor when you press a sensor program 
button, press and release a tamper switch, press a sensor test button, or put a sensor into 
alarm.
Note  
The hardwire inputs must have sirens or hardwire sensors with 47k Ohm resistors connected 
between the DCOUT and HWIN1 or HWIN2 terminals before learning in a sensor. If one of 
these connections is not made, the panel will learn in a hardwire zone.
Note  
If you are installing a sensor on a gun case, jewelry box, or similar usage, and the sensor is 
active in level one, you must sub-disarm to avoid putting the panel into alarm when the sensor 
and the magnet are separated.
The following table, “Device Programming,” describes the programming button loca-
tion for each device.
When adding (learning) sensors, the panel uses an ascending numbering sequence start-
ing with 1. You can override this by entering the desired sensor number using the num-
bered keys.
Device Programming
Device
To Program 
Door/Window Sensor
Press button on top of sensor (cover removed) 
or trip tamper
Motion Sensor
Press button on back of sensor (mounting plate 
removed) or trip tamper
Smoke Sensor
Trip tamper, press test button, remove from 
base or put sensor in alarm
Keychain Touchpad
Press and hold Lock & Unlock buttons together
ELM Keychain Touchpad
Remote Handheld Touchpad
Press the EMERGENCY buttons
2-Way RF Touchpad
Press Lights Off button 6 times
Hardwire Sensors
Separate sensor from magnet
CO Alarm
Plug in the module wait 5-7 seconds press and 
hold the test button for 9 beeps
Freeze & Water
Trip tamper or press and hold button on top of 
the sensor (cover removed) until control panel 
confirms programming. If button is not held 
down long enough, SYSTEM STATUS reports 
sensor as open.
Dialog RF Electronic Thermostat
Panel automatically recognizes thermostat dur-
ing thermostat power-up.
Press
Hold
Hold
Flash Flash
Flash
Hold until LED is done flashing. 
Press
Press
Hold
Flash
Flash Flash