System Data
Maximum Number 
of Station 
Instruments Per 
Line
1 for a KX-T7531/KX-T7533/KX-T7536/KX-T7230/KX-T7235/KX-T7250 or a 
single line telephone.
2 for by parallel connection of a digital proprietary telephone and a single line 
telephone.
Ring Voltage
80 Vrms at 25 Hz depending on the Ringing Load
Primary Power
110 V AC-240 V AC, 50 Hz/60 Hz, 58 W (max.)
(When power is off by the power switch: 1.2 W)
Backup Batteries
Total voltage: 24 V DC
Maximum current: 2.3 A
Central Office Loop 
Limit
1,600  max.
Environmental 
Requirements
0 °C-40 °C, 10 %-90 % relative humidity (no condensation)
Door Opener
60 V DC, 1 A (max.)/40 V AC, 1 A (max.)
Second Ringer 
Relay
60 V DC, 1 A (max.)/40 V AC, 1 A (max.)
External Relay
60 V DC, 1 A (max.)/40 V AC, 1 A (max.)
*
Install the KX-TD61280 for expansion of CO lines and the KX-TD61260/KX-TD61261/KX-TD61263 
for expansion of doorphones. 
Item
Maximum Quantity
Operator
2
System Speed Dialling
500
Station Speed Dialling
10 per extension
Call Park Areas
10
Toll Restriction Classes
8
Extension Groups
8
Class of Service
8
Hunting Group
32
Item
Description