Panasonic PT-L6600UL Installation Guide

Page of 8
Signal Level
Contents
Description
Sync. method
Asynchronous
Synchronizes every 1 character (8 
bits)
Baud rate
Conforms 
to
9 600 bps
Data transfer speed
Parity
 RS-232C 
None
Error detection method
Character length
standard
8 bits
Number of bit composing 1 character
Stop bit
1 bit
Uses stop bit when asynchronous 
method
X parameter
Not used
S parameter
Not used
6.4. Basic Format
The data sent from the PC to the projector is transmitted in the format shown below.
Cautions:
When it is unnecessary to designate an ID code, send the format without the part to 
ID designate it. In this case, the projector sends a call back to the PC irrespective of 
the projector ID setting.
Add a parameter when the command function is required of it.
If sending multiple commands, check that a call back has been received from the 
projector for one command before sending the next command.
Notes:
When a command which does not require parameters is sent, the colon (:) is not 
required.
If a command is sent with a projector ID specified, the projector will return call back 
only if the ID contained in the command matches the projector ID or the projector ID 
is set to ALL.
Projector ID supported on the RS-232C interface is 00 (ALL) to 99.
When using control from REMOTE terminal, commands cannot be received at SERIAL 
terminal.
6.5. Control / Query Commands
12