You can manually override Automatic Day/Night modes. (See “Manual Day/Night Mode” on 
page 35
.)
Digital Pad
Description
Digital pad settings allow adjustment of call levels for different call types. There are 29 pad classes in 
the System. For pad class, a volume adjustment is assigned for a connection to any pad class 
assignment. The volume adjustment is between -30dB and +30 dB.
There are 8 extension pad classes and 16 trunk pad classes. In addition, there are pad classes for 
conference calls, page port, MFR, RAI Modem, and Conference Call Unit. One pad class is currently 
not used.
For instance, a call from an extension assigned to extension pad class 1 to a trunk assigned to trunk 
pad class 3 would received the volume adjustment assigned to this connection combination.
Hardware Requirements
N/A
Considerations
N/A
Direct Inward System Access 
(All Versions)
Description
Direct Inward System Access (DISA) gives off-site users dial-in access to the System. You access 
DISA from an outside location by entering a digit number assigned to a DISA trunk.
For security reasons, sixteen incoming DISA ID codes/Toll Restriction Service (TRS) (Call Barring) 
class can be assigned. If a code is assigned, it must be entered as soon as the DISA trunk answers. 
Operation
To make a DISA call to an extension:
Action
Result
1.   From an outside location, enter the DISA trunk number. 
DISA dial tone
2.   If an incoming DISA code is assigned enter the DISA code 
(up to 10 digits). Otherwise, proceed to step 3.
3.   Dial the extension number.