Panasonic ICX Manual

Page of 60
Built-In ACD Supervisor Guide
Section 521
ICX-5.0-521 (ACD 4.0)
ICX (International) issued October 2000
11
Operation
The following describes the
 
operation in each of the processes.
EDIT (FF1)
This command resets the current setting of displayed program lines. Edit is 
repeated from the specified program line through to the currently registered 
final program line (excluding the END/DISC line).
The following screen display shows an example of selection and setting of the 
SEARCH command.
1. Press 
soft keys 12, or 3 or 67 or 8 for the command to be set, 
and press the HOLD key.
Example: Press soft key 3 to select SEARCH.
6
RET
Program Line 
Number Set-
ting 1 to 20 
(max. 20 
lines) 
(must be set)
Count Set-
ting 1 to 255 
(times) 
(must be set)
Return
• Repeats the program from the line number speci-
fied in parameter 1 up to this line for the count 
specified in parameter 2.
7
RAD
Port #
Recorded Announcement Device
• The caller hears MOH if the RAD port# is invalid 
or incorrect.
• The ICX Built-in ACD must use different RAD 
ports than Easy Run Courier ACD.
• RAD equipment will connect to AEC ports.
• No start or stop control method will be provided 
to control the RAD equipment.  RAD equipment 
must be capable of operating in the continuous 
play mode.
• Up to 8 RAD devices can be connected to AEC’s 
per system.
• This command must be followed by a SEARCH, 
FWD or FWDVM command.
• For programming (See Section 400 Programming 
Manual on page 1-168)
No
Com-
mand
Parameter1
Parameter2
Parameter3
Description
SEARCH 1,020,010
03:Select Cmd.
FWD
FWDVM
PLAY
RET
SEARCH
RAD
List