Puls CD5.121 DC/DC Converter Specification Guide

Page of 21
 
 
CD5.121
 
 
CD-Series 
DC/DC Converter 12V, 8A 
 
 
4.  S
OFT
-
START AND 
I
NPUT 
I
NRUSH 
C
URRENT 
S
URGE
 
 
Inrush current limitation 
An active inrush limitation circuit (inrush limiting resistor which is bypassed by a relay contact) limits the input inrush 
current after turn-on of the input voltage. 
The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. 
 
Inrush current 
max. 
1.6A
peak
 
-25°C to +70°C, input: 24Vdc 
 typ. 
1.2A
peak
 
-25°C to +70°C, input: 24Vdc 
Inrush energy 
typ. 
negligible 
-25°C to +70°C, input: 24Vdc 
 
 
Fig. 4-1   Input inrush current, typical behavior 
 
 
 
Input Current
Input Voltage
Output Voltage
 
 
 
Input:  
24Vdc 
Output:  
12V, 8A, constant current load 
Ambient: 25°C 
 
Upper curve: 
Input current 2A / DIV 
Middle curve: 
Input voltage 20V / DIV 
Lower curve: 
Output voltage 10V / DIV 
Time basis:  
100ms / DIV 
 
 
Soft-start function: 
After the DC/DC converter is turned on, the internal output current rises slowly to its nominal value. This method 
charges the output capacitors (internal and external capacitors) slowly and avoids high input currents during turn-on. 
High input currents can produce a high voltage drop on the input wiring (especially with long and thin cables) which 
reduces the terminal voltage on the DC/DC converter. If the terminal voltage is below the shut-down voltage, the 
DC/DC converter will turn-off and will make a new start-up attempt. This effect is avoided with the integrated soft-
start function. Please note, that this function increases the rise time of the output voltage by a small amount. 
 
 
Fig. 4-2  Soft-start behavior 
 
 
 
Input Current
Output Voltage
 
 
 
Input:  
24Vdc 
Output:  
12V, 8A, constant current load 
Ambient: 25°C 
No additional external output capacitors 
 
Upper curve: 
Input current 2A / DIV 
Lower curve: 
Output voltage 5V / DIV 
Time basis:  
20ms / DIV 
 
Oct 2009 / Rev. 1.3  DS-CD5.121-EN 
All parameters are specified at 12V, 8A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
5/21