Puls CD5.121 DC/DC Converter Specification Guide

Page of 21
 
 
CD5.121
 
 
CD-Series 
DC/DC Converter 12V, 8A 
 
 
3.  I
NPUT 
V
OLTAGE
 
 
Input voltage 
nom. 
DC 24V 
 
Input voltage range 
 
18.0-32.4Vdc full 
specified 
 
 
14.4-18.0Vdc 
maximal 60 seconds or with de-rating see Fig. 3-2
 max. 
36.0Vdc 
absolute maximum continuous input voltage with no 
damage to the DC/DC converter 
Allowed voltage between input 
and earth 
max. 60Vdc 
or 
42.2Vac 
in case the output voltage is not grounded. 
Allowed input ripple voltage 
max. 
5Vpp 
47Hz-40kHz, the momentary input voltage must always 
be within the specified limits. 
Turn-on voltage 
typ. 
17.5Vdc 
steady-state value, see Fig. 3-1
 
Shut-down voltage 
typ. 
14.0Vdc 
steady-state value, see Fig. 3-1
 
 
 
typ. 
35.0Vdc 
steady-state value, see Fig. 3-1
Input current 
typ. 
4.6A 
at 24Vdc input and output 12V, 8A, see Fig. 3-4
Start-up delay 
typ. 
420ms 
Rise time 
typ. 
210ms 
0mF, 12V, constant current load 5A, see Fig. 3-3
 
 
 
typ. 
240ms 
8mF, 12V, constant current load 5A, see Fig. 3-3
Turn-on overshoot 
max. 
500mV 
Input capacitance 
typ. 
3 000μF 
external capacitors on the input voltage bus are allowed 
without any limitations. 
 
 
 
Fig. 3-1   Input voltage range 
 
Fig. 3-2   Allowable output current below 18V 
input voltage 
 
Tur
n
-o
n
17.
5
V
dc
V
IN
P
OUT
S
hut
-do
w
n
32.
4
V
dc
14.
0
V
dc
18.
0
V
dc
Rated input range
35.
0
V
dc
 
 
0
2
4
6
8
10A
14
16
18
20
24Vdc
Input Voltage
Output Current
22
(a)
(b)
 (a) Ambient < 45°C
 (b) Ambient < 60°C
 
 
Fig. 3-3   Turn-on behavior, definitions 
 
Fig. 3-4   Input current vs. output load 
 
Start-up
delay
Rise
Time
Ov
ersh
oot
- 5%
Output
Voltage
Input
Voltage
 
 
10A
1
2
3
5
7
0
2
4
6
8A
9
Output Current
4
6
8
Inp
ut:
 24
Vd
c
Input
Current,
typ.
Inp
ut
: 1
8V
dc
 
 
Oct 2009 / Rev. 1.3  DS-CD5.121-EN 
All parameters are specified at 12V, 8A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
4/21