Moxa PTC-101-M-LC-LV Specification Guide

Page of 3
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Ethernet Media Converters
Introduction
The PTC-101 Ethernet-to-fiber media converters convert from 
10/100BaseT(X) to 100BaseFX. Models are available with either SC, 
ST, or LC connectors. The PTC-101 converters eliminate the need for 
10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
 
Link Fault Pass-Through (LFP)
 
Power failure alarm by relay output (LV model only)
 
-40 to 85°C operating temperature range
 
Redundant dual DC power inputs
 
Integrated high-reliability power supply eliminates the need for 
 
external power transformer
Specifications
additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols 
with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to 
provide a total solution for your industrial Ethernet networks.
Technology
Standards: 
IEEE 802.3 for 10BaseT 
IEEE 802.3u for 100BaseT(X), 100BaseFX
Interface
RJ45 Ports: 10/100BaseT(X)
Fiber Ports: 100BaseFX (SC/ST/LC connectors)
LED Indicators: PTC-101-HV series: PWR1, Fiber Link, 10/100M (TP port) 
PTC-101-LV series: PWR1, PWR2, Fiber Link, 10/100M (TP port)
DIP Switches:
    
Alarm Contact: One relay output with current carrying capacity of 1 A @ 24 
VDC
Optical Fiber
    
Physical Characteristics
Housing: Aluminum, IP30 protection
Dimensions: 122.5 x 90 x 20 mm (4.82 x 3.54 x 0.79 in)
Weight: 
Product only: 690 g 
Packaged: 875 g
Environmental Limits
Operating Temperature: -40 to 85°C (-40 to 185°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements
Input Voltage:
    
Connection: Removable terminal block
Overload Current Protection: 1.6 A (protects against two signals shorted 
together)
Reverse Polarity Protection: Present
Regulatory Approvals
Safety: UL 60950-1
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: 
EN61000-4-2 Edition 1.2: 2001-04 (Level 4) 
EN61000-4-3: 1995+A1: 2001  
IEC 61000-4-3: 2002+A1: 2002 (Level 3) 
EN61000-4-4: 2004 (Level 4) 
EN61000-4-5: 2001-04 (Level 4) 
EN61000-4-6: 2004-11 (Level 3) 
EN61000-4-8: 2001-03 (Level 5) 
EN61000-4-11: 2004-03 (Criteria B)
Power Automation: IEC 61850-3, IEEE 1613
Rail Traffic: EN50155/EN50121-4
Note: Refer to the “Environmental Type Tests” table below for more detailed information.
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
IEC 61850-3 and EN50155 Ethernet-to-fiber media converters
DIP No.
Function
ON
OFF
1
Auto Negotiation
Enable
Disable
2
Force TP Speed
100 Mbps
10 Mbps
3
Force TP Duplex
Full Duplex
Half Duplex
4
Link Fault Pass Throuth
Enable
Disable
5
Operating Mode
Store-and-Forward
Pass Through
The default setting for all DIP switches is ON.
100BaseFX
Multi-mode
Single-mode
Wavelength
1300 nm
1310 nm
Max. TX
-10 dBm
0 dBm
Min. TX
-20 dBm
-5 dBm
RX Sensitivity
-32 dBm
-34 dBm
Link Budget
12 dB
29 dB
Typical Distance
5 km a
4 km b
40 km c
Saturation
-6 dBm
-3 dBm
a. 50/125 μm, 800 MHz*km fiber optic cable
b. 62.5/125 μm, 500 MHz*km fiber optic cable
c. 9/125 μm, 3.5 PS/(nm*km) fiber optic cable
Power Supply Type
Power Consumption
Fuse Rating
LV - DC
20 to 72 VDC
170 mA @ 20 VDC
3.15A(T) 2
HV - AC
85 to 264 VAC
73 mA @ 85 VAC
3.15A(T) 2
HV - DC
88 to 300 VDC
47 mA @ 88 VDC
3.15A(T) 2
PTC-101 Series